The working principle of the electric globe valve is to make the valve unblocked or blocked by rotating the valve. The gate valve switch is light, small in size, can be made into a large diameter, reliable sealing, simple structure, convenient maintenance, sealing surface and spherical surface are often in a closed state, not easy to be eroded by media, and are widely used in various industries. If you w
Read more >>What is Pneumatic Control Valve/Pneumatic Regulating Valve? COVNA Pneumatic Control Valve includes ZJHP series and ZJHM series. ZJHP/ZJHM series mini pneumatic diaphragm regulaton valves,developed by our company using the advanced technology inside and outside China according to the IEC standard,are a new generation actuators. The product comprises a multiple spring zero adjustable actuator, a low flow res
Read more >>1.applicability The fluid in the pipeline must be consistent with the medium calibrated in the selected solenoid valve series. The temperature of the fluid must be less than the calibration temperature of the selected solenoid valve. The maximum working pressure difference should be less than the maximum calibration pressure of the solenoid valve; generally, the solenoid valve works in one direction, so pay atte
Read more >>1. Solenoid valves are divided into three categories in principle: 1) Direct acting solenoid valve: Principle: When energized, the electromagnetic coil generates electromagnetic force to lift the closing member from the valve seat, and the valve opens; when the power is off, the electromagnetic force disappears, the spring presses the closing member on the valve seat, and the valve closes. Features: It can work no
Read more >>1. The solenoid valve does not work after being energized Check whether the power wiring is bad, re-wiring and connector connection Check whether the power supply voltage is in the working range -, adjust the normal position range Whether the coil is desoldered and re-soldered The coil is shorted, replace the coil Whether the working pressure difference is inappropriate, adjust the pressure difference
Read more >>First, check whether the solenoid valve solenoid coil is faulty. Give the two-position valve an open or close signal on the DCS, and then see if the solenoid valve gains or loses power. Generally, you can listen to the sound at the scene. If you can't hear it, there must be a problem with the coil. As for the solenoid valve itself, is there a problem? If there is a problem with the solenoid coil, first chec
Read more >>